0.6/1KV FA TPYCY

Description

Description

Standards

  • Test
    IEC 60332-3 Cat.A
  • National
    JIS C 3410-1999; JIS C 3410-1999

Application

  • Power circuit upto 0.6/1kV, Power & Lighting circuit
  • Fixed installation power & lighting in both explosion risk and safe areas, general purposes.

This product is part of our Shiplink® offer

 

Construction details

  • Conductor : Tinned annealed copper wire, stranded
  • Insulation : EPR insulation identified
  • Individual Copper wire shield braid : End of ‘-S’ type
  • Cabling with filler (if necessary)
  • Common Copper wire shield braid : End of ‘S’ type
  • PVC sheath
  • Metal wire armour : Galvanized steel wire braiding
  • Paint : In case of protective covered cable, paint is dispensable.
  • PVC protective covering

 

Standard applied

  • Design guideline : JIS C 3410 (1999)
  • Material properties :
    • JIS C 3410 Insulation, EPR
    • JIS C 3410 Sheath, PVC
  • Flame retardant :
    • IEC 60332-1
    • IEC 60332-3, Cat. A, ‘FA--’ type only
  • Cable marking of cold properties:
    - ‘ICE’ type : CSA C22.2 No. 03, Cold bending -40℃, Cold impact -35℃
    - ‘-35DEG.’ type : CSA C22.2 No. 03, Cold bending -35℃

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanized steel wire braiding
Conductor flexibility
Stranded class 2
Conductor material
Copper or tinned copper
Conductor shape
Circular stranded (RM)
Insulation
EPR
Outer sheath
PVC
Screen
Copper wire, tinned, separator tape (optional)

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
2.5 mm²
Approximate weight
355 kg/km
Nominal outer diameter
15.5 mm
Average insulation thickness
1.0 mm
Conductor diameter
2.0 mm
Diameter over armour
13.5 mm
Diameter over filler / inner sheath
12.2 mm
Diameter over insulation
0.0 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Flame retardant
-
Operating temperature, range
- °C
Standard
JIS

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close