TFR-CV 6/10kV
TFR-CV 6/10kV 1x 16mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 16 mm²
- Outer Diameter: 20 mm
- Approximate weight: 470 kg/km
TFR-CV 6/10kV 1x 25mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 25 mm²
- Outer Diameter: 21 mm
- Approximate weight: 680 kg/km
TFR-CV 6/10kV 1x 35mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 35 mm²
- Outer Diameter: 22 mm
- Approximate weight: 690 kg/km
TFR-CV 6/10kV 1x 50mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Outer Diameter: 23 mm
- Approximate weight: 850 kg/km
TFR-CV 6/10kV 1x 70mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Outer Diameter: 25 mm
- Approximate weight: 1100 kg/km
TFR-CV 6/10kV 1x 95mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Outer Diameter: 27 mm
- Approximate weight: 1390 kg/km
TFR-CV 6/10kV 1x 120mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Outer Diameter: 28 mm
- Approximate weight: 1680 kg/km
TFR-CV 6/10kV 1x 150mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Outer Diameter: 30 mm
- Approximate weight: 1670 kg/km
TFR-CV 6/10kV 1x 185mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Outer Diameter: 32 mm
- Approximate weight: 2360 kg/km
TFR-CV 6/10kV 1x 240mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Outer Diameter: 35 mm
- Approximate weight: 3020 kg/km
TFR-CV 6/10kV 1x 300mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Outer Diameter: 37 mm
- Approximate weight: 3640 kg/km
TFR-CV 6/10kV 1x 400mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Outer Diameter: 40 mm
- Approximate weight: 4510 kg/km
TFR-CV 6/10kV 1x 500mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 500 mm²
- Outer Diameter: 43 mm
- Approximate weight: 5650 kg/km
TFR-CV 6/10kV 3x 16mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Outer Diameter: 39 mm
- Approximate weight: 1510 kg/km
TFR-CV 6/10kV 3x 25mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Outer Diameter: 41 mm
- Approximate weight: 1945 kg/km
TFR-CV 6/10kV 3x 35mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Outer Diameter: 43 mm
- Approximate weight: 2330 kg/km
TFR-CV 6/10kV 3x 50mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Outer Diameter: 46 mm
- Approximate weight: 2810 kg/km
TFR-CV 6/10kV 3x 70mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Outer Diameter: 50 mm
- Approximate weight: 3620 kg/km
TFR-CV 6/10kV 3x 95mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Outer Diameter: 53 mm
- Approximate weight: 4545 kg/km
TFR-CV 6/10kV 3x 120mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Outer Diameter: 57 mm
- Approximate weight: 5680 kg/km
TFR-CV 6/10kV 3x 150mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Outer Diameter: 60 mm
- Approximate weight: 6410 kg/km
TFR-CV 6/10kV 3x 185mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Outer Diameter: 64 mm
- Approximate weight: 7700 kg/km
TFR-CV 6/10kV 3x 240mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Outer Diameter: 69 mm
- Approximate weight: 9915 kg/km
TFR-CV 6/10kV 3x 300mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Outer Diameter: 74 mm
- Approximate weight: 12920 kg/km
Description
Description
Standards
-
NationalKS C IEC 60502-2; KWS 413
Application
Power cable for residential, commercial building and distribution circuit.
The flame retardant cable for tray conformed to the standard (for technique of electrical equipment)
1. Conductor: Stranded annealed round plain copper, Class 2
2. Conductor screen: Extruded semi-conductive compound or taping
3. Insulation: Cross-linked Polyethylene (XLPE).
4. Insulation screen:
5. Shield: Copper tape
6. Unit: Cabling circular shielded solid wire in case of more 3 cores
7. Outer sheath: Black Flame retardant PVC (TFR PVC)
Colors
1 core : Natural color (XLPE)
3 cores: Black, White, Red
TFR-CV 6/10kV design
##image:56003## |
Inner Semi-conductive material Insulation Outer Semi-Conductive material Shield Binder Tape Outer Sheath(FR PVC)
|
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania