TFR-CVV-S. TFR-CVV-SB 0.6/1kV

Products

TFR-CVV-S , TFR-CVV-SB 2x1.5mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 12 mm
  • Approximate weight: 175 kg/km

 

TFR-CVV-S , TFR-CVV-SB 2x2,5mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 13 mm
  • Approximate weight: 210 kg/km

 

TFR-CVV-S , TFR-CVV-SB 2x4mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 280 kg/km

 

TFR-CVV-S , TFR-CVV-SB 2x6mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 16 mm
  • Approximate weight: 335 kg/km

 

TFR-CVV-S , TFR-CVV-SB 2x10mm²

Nexans ref.

  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 17.5 mm
  • Approximate weight: 480 kg/km

 

TFR-CVV-S , TFR-CVV-SB 3x1.5mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 12.5 mm
  • Approximate weight: 210 kg/km

 

TFR-CVV-S , TFR-CVV-SB 3x2,5mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 13.5 mm
  • Approximate weight: 250 kg/km

 

TFR-CVV-S , TFR-CVV-SB 3x4mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 360 kg/km

 

TFR-CVV-S , TFR-CVV-SB 3x6mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 450 kg/km

 

TFR-CVV-S , TFR-CVV-SB 3x10mm²

Nexans ref.

  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 590 kg/km

 

TFR-CVV-S , TFR-CVV-SB 4x1.5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 13.5 mm
  • Approximate weight: 250 kg/km

 

TFR-CVV-S , TFR-CVV-SB 4x2,5mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 325 kg/km

 

TFR-CVV-S , TFR-CVV-SB 4x4mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 440 kg/km

 

TFR-CVV-S , TFR-CVV-SB 4x6mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 550 kg/km

 

TFR-CVV-S , TFR-CVV-SB 4x10mm²

Nexans ref.

  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 770 kg/km

 

TFR-CVV-S , TFR-CVV-SB 5x1.5mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 14.5 mm
  • Approximate weight: 300 kg/km

 

TFR-CVV-S , TFR-CVV-SB 5x2,5mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 380 kg/km

 

TFR-CVV-S , TFR-CVV-SB 5x4mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 520 kg/km

 

TFR-CVV-S , TFR-CVV-SB 5x6mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 650 kg/km

 

TFR-CVV-S , TFR-CVV-SB 5x10mm²

Nexans ref.

  • Number of cores: 5
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 920 kg/km

 

TFR-CVV-S , TFR-CVV-SB 6x1.5mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 320 kg/km

 

TFR-CVV-S , TFR-CVV-SB 6x2,5mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 420 kg/km

 

TFR-CVV-S , TFR-CVV-SB 6x4mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 635 kg/km

 

TFR-CVV-S , TFR-CVV-SB 6x6mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 790 kg/km

 

TFR-CVV-S , TFR-CVV-SB 6x10mm²

Nexans ref.

  • Number of cores: 6
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 1100 kg/km

 

TFR-CVV-S , TFR-CVV-SB 7x1.5mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 15.5 mm
  • Approximate weight: 360 kg/km

 

TFR-CVV-S , TFR-CVV-SB 7x2,5mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 470 kg/km

 

TFR-CVV-S , TFR-CVV-SB 7x4mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 19.5 mm
  • Approximate weight: 670 kg/km

 

TFR-CVV-S , TFR-CVV-SB 7x6mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 880 kg/km

 

TFR-CVV-S , TFR-CVV-SB 7x10mm²

Nexans ref.

  • Number of cores: 7
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 1230 kg/km

 

TFR-CVV-S , TFR-CVV-SB 8x1.5mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 16.5 mm
  • Approximate weight: 420 kg/km

 

TFR-CVV-S , TFR-CVV-SB 8x2,5mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 17.5 mm
  • Approximate weight: 530 kg/km

 

TFR-CVV-S , TFR-CVV-SB 8x4mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 21.5 mm
  • Approximate weight: 780 kg/km

 

TFR-CVV-S , TFR-CVV-SB 8x6mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 23.5 mm
  • Approximate weight: 1000 kg/km

 

TFR-CVV-S , TFR-CVV-SB 8x10mm²

Nexans ref.

  • Number of cores: 8
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 1420 kg/km

 

TFR-CVV-S , TFR-CVV-SB 10x1.5mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 18 mm
  • Approximate weight: 500 kg/km

 

TFR-CVV-S , TFR-CVV-SB 10x2,5mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 20 mm
  • Approximate weight: 660 kg/km

 

TFR-CVV-S , TFR-CVV-SB 10x4mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 940 kg/km

 

TFR-CVV-S , TFR-CVV-SB 10x6mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 1200 kg/km

 

TFR-CVV-S , TFR-CVV-SB 10x10mm²

Nexans ref.

  • Number of cores: 10
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 30.5 mm
  • Approximate weight: 1720 kg/km

 

TFR-CVV-S , TFR-CVV-SB 12x1.5mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 18.5 mm
  • Approximate weight: 565 kg/km

 

TFR-CVV-S , TFR-CVV-SB 12x2,5mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 730 kg/km

 

TFR-CVV-S , TFR-CVV-SB 12x4mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 24.5 mm
  • Approximate weight: 1100 kg/km

 

TFR-CVV-S , TFR-CVV-SB 12x6mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 26.5 mm
  • Approximate weight: 1420 kg/km

 

TFR-CVV-S , TFR-CVV-SB 12x10mm²

Nexans ref.

  • Number of cores: 12
  • Conductor cross-section: 10 mm²
  • Outer Diameter: 30.5 mm
  • Approximate weight: 2000 kg/km

 

TFR-CVV-S , TFR-CVV-SB 15x1.5mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 20.5 mm
  • Approximate weight: 690 kg/km

 

TFR-CVV-S , TFR-CVV-SB 15x2,5mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 22.5 mm
  • Approximate weight: 915 kg/km

 

TFR-CVV-S , TFR-CVV-SB 15x4mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 27.5 mm
  • Approximate weight: 1350 kg/km

 

TFR-CVV-S , TFR-CVV-SB 15x6mm²

Nexans ref.

  • Number of cores: 15
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 29.5 mm
  • Approximate weight: 1730 kg/km

 

TFR-CVV-S , TFR-CVV-SB 20x1.5mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 22 mm
  • Approximate weight: 870 kg/km

 

TFR-CVV-S , TFR-CVV-SB 20x2,5mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 25 mm
  • Approximate weight: 1140 kg/km

 

TFR-CVV-S , TFR-CVV-SB 20x4mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 30 mm
  • Approximate weight: 1730 kg/km

 

TFR-CVV-S , TFR-CVV-SB 20x6mm²

Nexans ref.

  • Number of cores: 20
  • Conductor cross-section: 6 mm²
  • Outer Diameter: 33 mm
  • Approximate weight: 2245 kg/km

 

TFR-CVV-S , TFR-CVV-SB 30x1.5mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 1.5 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 1230 kg/km

 

TFR-CVV-S , TFR-CVV-SB 30x2,5mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 2.5 mm²
  • Outer Diameter: 29 mm
  • Approximate weight: 1620 kg/km

 

TFR-CVV-S , TFR-CVV-SB 30x4mm²

Nexans ref.

  • Number of cores: 30
  • Conductor cross-section: 4 mm²
  • Outer Diameter: 36 mm
  • Approximate weight: 2500 kg/km

 

Description

Description

Standards

  • National
    KS C IEC 60502-1; KWS 411

Application

Copper tape or copper braid shielded control cable for distribution circuit in residential or commercial building and distribution circuit.
The flame retardant cable for tray conformed to the standard of technique of electrical equipment.

Design

1. Conductor: Stranded annealed round plain copper, Class 2

2. Insulation: PVC, operating temperature 70°C.

3. Unit: Cabling circularly insulated solid wire in case of more than 2 cores

4. Shield: Copper tape or copper braid

4. Outer sheath: Black flame retardant black PVC (TFR PVC)

 

Colors

2 cores: White /Black
3 cores: White / Black /Red,
4 cores: White / Black / Red / Green
More 5 cores: Numbering on black or red core. The others are white

Certification

KETI
KWS (Collective standard)

TFR-CVV-S. TFR-CVV-SB 0.6/1kV design

##image:56057##

Conductor 

Insulation 

Filler

PS tape 

Shield (copper tape or braid)

Binder tape 

Outer sheath (TFR PVC)

 

 

The values of insulation resistance is not defined but only constant number of insulation resistance is defined.
(K=min. 36.7MΩ.km at room temperature, min. 0.037MΩ.km at 70℃) 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Annealed copper
Type of conductor
Stranded, class 2
Insulation
PVC
Outer sheath
TPR (thermoplastic rubber)

Electrical characteristics

Electrical characteristics

Test voltage
3500 V
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-15 ... 60 °C
Flame retardant
KSC IEC 60332-3
Bending factor when installed
12 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close